This is the latest recevied telemetry packets stored in our database for station/object WA6ODP-4. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Value1* | Value2* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1719800703 | 336 | 96.8 | 48.3 | 90.3 | 0 |
1719799802 | 334 | 97.9 | 49.4 | 91.4 | 0 |
1719798902 | 334 | 98.9 | 49.9 | 92.4 | 0 |
1719798002 | 333 | 99.8 | 49.9 | 93.3 | 0 |
1719797103 | 334 | 100.8 | 51.5 | 94.3 | 0 |
1719796202 | 333 | 101.6 | 51.5 | 95 | 0 |
1719795301 | 333 | 102.2 | 52.1 | 95.7 | 0 |
1719794402 | 333 | 102.9 | 52.1 | 96.1 | 0 |
1719793503 | 334 | 103.3 | 52.6 | 96.7 | 0 |
1719792602 | 333 | 103.9 | 53.2 | 97.8 | 0 |
1719791701 | 334 | 104.7 | 53.2 | 97.8 | 0 |
1719790802 | 334 | 105.1 | 53.7 | 98.4 | 0 |
1719789902 | 334 | 105.5 | 53.7 | 98.7 | 0 |
1719789002 | 335 | 105.8 | 53.7 | 99 | 0 |
1719788103 | 334 | 106.1 | 54.2 | 99.4 | 0 |
1719787202 | 335 | 106.2 | 54.2 | 99.6 | 0 |
1719786302 | 335 | 106.4 | 54.2 | 99.6 | 0 |
1719785402 | 335 | 106.4 | 54.2 | 99.5 | 0 |
1719784501 | 336 | 106.6 | 55.3 | 99.8 | 0 |
1719783602 | 335 | 106.6 | 54.8 | 99.8 | 0 |
1719782702 | 335 | 106.7 | 54.8 | 100 | 0 |
1719781802 | 336 | 106.4 | 54.8 | 99.6 | 0 |
1719780901 | 336 | 106 | 54.2 | 99.3 | 0 |
1719780002 | 335 | 105.7 | 54.2 | 98.9 | 0 |
1719779103 | 336 | 105.1 | 54.2 | 98.2 | 0 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 0.1, 0
Value3: 0, 0.1, 0
Value4: 0, 0.1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)