This is the latest recevied telemetry packets stored in our database for station/object ED5YAM. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | VOLT* | TMP* | TX* | WIND* | CHG* |
---|---|---|---|---|---|
1720160465 | 500 | 601 | 999 | 88 | 510 |
1720160285 | 500 | 601 | 999 | 101 | 510 |
1720160105 | 499 | 601 | 999 | 92 | 510 |
1720159925 | 499 | 601 | 999 | 102 | 510 |
1720159745 | 499 | 601 | 999 | 62 | 509 |
1720159565 | 499 | 601 | 999 | 65 | 509 |
1720159385 | 499 | 601 | 999 | 86 | 509 |
1720159204 | 493 | 601 | 682 | 81 | 509 |
1720159024 | 500 | 601 | 999 | 48 | 508 |
1720158844 | 500 | 601 | 999 | 112 | 508 |
1720158664 | 500 | 601 | 999 | 55 | 507 |
1720158484 | 500 | 601 | 999 | 77 | 507 |
1720158304 | 500 | 601 | 999 | 106 | 507 |
1720158124 | 500 | 601 | 999 | 105 | 507 |
1720157944 | 499 | 601 | 999 | 129 | 506 |
1720157760 | 499 | 601 | 999 | 89 | 506 |
1720157578 | 499 | 601 | 999 | 117 | 506 |
1720157397 | 499 | 601 | 999 | 94 | 505 |
1720157217 | 499 | 601 | 999 | 103 | 505 |
1720157037 | 499 | 601 | 999 | 131 | 505 |
1720156857 | 500 | 601 | 999 | 116 | 504 |
1720156677 | 499 | 601 | 999 | 131 | 504 |
1720156497 | 499 | 601 | 999 | 121 | 503 |
1720156317 | 499 | 601 | 999 | 125 | 503 |
1720156137 | 499 | 601 | 999 | 106 | 503 |
*Used Equation Coefficients:
VOLT: 0, 1, 0
TMP: 0, 1, 0
TX: 0, 1, 0
WIND: 0, 1, 0
CHG: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)