This is the latest recevied telemetry packets stored in our database for station/object VK4RMM-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Temp* | Battery* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1727473824 | 145 | 165 | 251 | 0 | 0 |
1727471991 | 144 | 162 | 250 | 0 | 0 |
1727470162 | 144 | 162 | 251 | 0 | 0 |
1727468337 | 144 | 159 | 251 | 0 | 0 |
1727466508 | 144 | 159 | 249 | 0 | 0 |
1727464679 | 145 | 159 | 250 | 0 | 0 |
1727462843 | 144 | 159 | 250 | 0 | 0 |
1727461009 | 144 | 160 | 250 | 0 | 0 |
1727459177 | 145 | 160 | 250 | 0 | 0 |
1727457351 | 145 | 160 | 250 | 0 | 0 |
1727455513 | 145 | 160 | 250 | 0 | 0 |
1727453693 | 145 | 160 | 250 | 0 | 0 |
1727451862 | 145 | 161 | 250 | 0 | 0 |
1727450028 | 145 | 160 | 250 | 0 | 0 |
1727448191 | 145 | 161 | 251 | 0 | 0 |
1727446349 | 145 | 161 | 250 | 0 | 0 |
1727444512 | 145 | 161 | 250 | 0 | 0 |
1727442677 | 146 | 161 | 250 | 0 | 0 |
1727440833 | 145 | 161 | 250 | 0 | 0 |
1727438996 | 145 | 162 | 251 | 0 | 0 |
1727437150 | 146 | 162 | 250 | 0 | 0 |
1727435313 | 145 | 162 | 250 | 0 | 0 |
1727433476 | 145 | 162 | 251 | 0 | 0 |
1727431641 | 145 | 162 | 251 | 0 | 0 |
1727429806 | 146 | 162 | 250 | 0 | 0 |
*Used Equation Coefficients:
Temp: 0, 1, 0
Battery: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)