This is the latest recevied telemetry packets stored in our database for station/object ED4ZAA-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Temp* |
---|---|---|---|---|---|
1716485791 | 12.53 Volt | 70 Pkt | 60 Pkt | 69 Pcnt | -62 ºC |
1716478585 | 13.8 Volt | 60 Pkt | 60 Pkt | 66 Pcnt | -62 ºC |
1716474981 | 13.8 Volt | 80 Pkt | 70 Pkt | 63 Pcnt | -62 ºC |
1716471378 | 13.8 Volt | 110 Pkt | 70 Pkt | 60 Pcnt | -62 ºC |
1716467774 | 13.73 Volt | 70 Pkt | 60 Pkt | 64 Pcnt | -62 ºC |
1716464171 | 13.8 Volt | 80 Pkt | 70 Pkt | 67 Pcnt | -62 ºC |
1716460567 | 14.03 Volt | 100 Pkt | 90 Pkt | 84 Pcnt | -62 ºC |
1716456964 | 14.1 Volt | 90 Pkt | 80 Pkt | 67 Pcnt | -62 ºC |
1716453360 | 14.1 Volt | 70 Pkt | 60 Pkt | 69 Pcnt | -62 ºC |
1716449757 | 14.33 Volt | 90 Pkt | 70 Pkt | 61 Pcnt | -62 ºC |
1716446153 | 13.5 Volt | 130 Pkt | 100 Pkt | 56 Pcnt | -62 ºC |
1716442550 | 12.53 Volt | 110 Pkt | 80 Pkt | 63 Pcnt | -62 ºC |
1716438946 | 12.3 Volt | 100 Pkt | 80 Pkt | 57 Pcnt | -62 ºC |
1716435343 | 12.3 Volt | 70 Pkt | 60 Pkt | 60 Pcnt | -62 ºC |
1716431739 | 12.38 Volt | 110 Pkt | 80 Pkt | 66 Pcnt | -62 ºC |
1716428136 | 12.38 Volt | 90 Pkt | 70 Pkt | 53 Pcnt | -62 ºC |
1716424533 | 12.38 Volt | 120 Pkt | 90 Pkt | 62 Pcnt | -62 ºC |
1716420929 | 12.45 Volt | 100 Pkt | 90 Pkt | 72 Pcnt | -62 ºC |
1716417326 | 12.45 Volt | 60 Pkt | 50 Pkt | 88 Pcnt | -62 ºC |
1716413722 | 12.45 Volt | 50 Pkt | 50 Pkt | 64 Pcnt | -62 ºC |
1716410119 | 12.45 Volt | 60 Pkt | 60 Pkt | 65 Pcnt | -62 ºC |
1716406515 | 12.45 Volt | 60 Pkt | 50 Pkt | 62 Pcnt | -62 ºC |
1716402912 | 12.45 Volt | 70 Pkt | 60 Pkt | 78 Pcnt | -62 ºC |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -62
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)