This is the latest recevied telemetry packets stored in our database for station/object E25RIV-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | RxTraffic* | TxTraffic* | RxDrop* | RSSI* | Voltage* |
---|---|---|---|---|---|
1734979846 | 0 Pkt | 0 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734979222 | 0 Pkt | 0 Pkt | 0 Pkt | -67 dBm | 13.64 V |
1734978598 | 0 Pkt | 0 Pkt | 0 Pkt | -67 dBm | 13.64 V |
1734977974 | 0 Pkt | 0 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734977350 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734976726 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734976102 | 0 Pkt | 0 Pkt | 0 Pkt | -69 dBm | 13.62 V |
1734975478 | 0 Pkt | 0 Pkt | 0 Pkt | -67 dBm | 13.62 V |
1734974854 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734974231 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734973606 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.6 V |
1734972982 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734972358 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734971734 | 0 Pkt | 1 Pkt | 0 Pkt | -67 dBm | 13.62 V |
1734971110 | 0 Pkt | 0 Pkt | 0 Pkt | -68 dBm | 13.62 V |
1734970487 | 0 Pkt | 0 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734969862 | 0 Pkt | 0 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734969238 | 0 Pkt | 0 Pkt | 0 Pkt | -65 dBm | 13.62 V |
1734968614 | 0 Pkt | 0 Pkt | 0 Pkt | -67 dBm | 13.62 V |
1734967990 | 0 Pkt | 0 Pkt | 0 Pkt | -65 dBm | 13.62 V |
1734967366 | 0 Pkt | 1 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734966741 | 0 Pkt | 0 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734966117 | 0 Pkt | 0 Pkt | 0 Pkt | -66 dBm | 13.62 V |
1734965493 | 0 Pkt | 0 Pkt | 0 Pkt | -65 dBm | 13.6 V |
1734964869 | 0 Pkt | 0 Pkt | 0 Pkt | -65 dBm | 13.6 V |
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
RSSI: 0, -1, 0
Voltage: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)