Time | DC* | RxP-1h* | Dg1h* | Eff1h* | DC-1* |
---|---|---|---|---|---|
1734953509 | 10.95 Volt | 250 Pkt | 210 Pkt | 75 *100 | 0 Volt |
1734953209 | 10.88 Volt | 250 Pkt | 210 Pkt | 74 *100 | 0 Volt |
1734952909 | 10.95 Volt | 250 Pkt | 210 Pkt | 74 *100 | 0 Volt |
1734952610 | 10.95 Volt | 250 Pkt | 210 Pkt | 77 *100 | 0 Volt |
1734952310 | 10.95 Volt | 250 Pkt | 210 Pkt | 75 *100 | 0 Volt |
1734952010 | 11.03 Volt | 260 Pkt | 210 Pkt | 74 *100 | 0 Volt |
1734951709 | 11.03 Volt | 250 Pkt | 210 Pkt | 72 *100 | 0 Volt |
1734951410 | 11.03 Volt | 260 Pkt | 210 Pkt | 72 *100 | 0 Volt |
1734951109 | 10.8 Volt | 250 Pkt | 210 Pkt | 71 *100 | 0 Volt |
1734950810 | 10.8 Volt | 260 Pkt | 210 Pkt | 73 *100 | 0 Volt |
1734950510 | 10.95 Volt | 260 Pkt | 220 Pkt | 72 *100 | 0 Volt |
1734950210 | 10.95 Volt | 260 Pkt | 210 Pkt | 71 *100 | 0 Volt |
1734949910 | 10.95 Volt | 260 Pkt | 210 Pkt | 69 *100 | 0 Volt |
1734949610 | 10.95 Volt | 270 Pkt | 220 Pkt | 68 *100 | 0 Volt |
1734949310 | 10.95 Volt | 270 Pkt | 220 Pkt | 67 *100 | 0 Volt |
1734949010 | 10.95 Volt | 270 Pkt | 220 Pkt | 67 *100 | 0 Volt |
1734948710 | 10.95 Volt | 270 Pkt | 210 Pkt | 67 *100 | 0 Volt |
1734948410 | 10.95 Volt | 270 Pkt | 210 Pkt | 67 *100 | 0 Volt |
1734948110 | 10.95 Volt | 260 Pkt | 200 Pkt | 67 *100 | 0 Volt |
1734947810 | 11.03 Volt | 260 Pkt | 200 Pkt | 66 *100 | 0 Volt |
1734947510 | 11.1 Volt | 260 Pkt | 200 Pkt | 64 *100 | 0 Volt |
1734947210 | 11.18 Volt | 260 Pkt | 200 Pkt | 64 *100 | 0 Volt |
1734946910 | 11.25 Volt | 250 Pkt | 190 Pkt | 64 *100 | 0 Volt |
1734946610 | 11.18 Volt | 250 Pkt | 190 Pkt | 64 *100 | 0 Volt |
1734946310 | 11.1 Volt | 250 Pkt | 180 Pkt | 65 *100 | 0 Volt |
*Used Equation Coefficients:
DC: 0, 0.075, 0
RxP-1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
DC-1: 0, 0.075, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)