This is the latest recevied telemetry packets stored in our database for station/object OK1TZL. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Uin* | Rx1h* | Dg1h* | Rx10m* | Temp* |
---|---|---|---|---|---|
1734940527 | 13.88 Volt | 380 Pkt | 30 Pkt | 52 Pkt | 14.6 C |
1734937827 | 13.73 Volt | 390 Pkt | 30 Pkt | 54 Pkt | 14.6 C |
1734929728 | 13.88 Volt | 360 Pkt | 20 Pkt | 54 Pkt | 14.7 C |
1734927028 | 13.88 Volt | 350 Pkt | 20 Pkt | 47 Pkt | 14.7 C |
1734924328 | 13.88 Volt | 370 Pkt | 30 Pkt | 62 Pkt | 14.7 C |
1734921628 | 13.88 Volt | 340 Pkt | 30 Pkt | 51 Pkt | 14.7 C |
1734918928 | 13.88 Volt | 330 Pkt | 30 Pkt | 50 Pkt | 14.7 C |
1734916228 | 13.73 Volt | 350 Pkt | 30 Pkt | 49 Pkt | 14.7 C |
1734913528 | 13.88 Volt | 350 Pkt | 30 Pkt | 58 Pkt | 14.8 C |
1734910828 | 13.88 Volt | 320 Pkt | 30 Pkt | 57 Pkt | 14.8 C |
1734908128 | 13.88 Volt | 320 Pkt | 30 Pkt | 45 Pkt | 14.8 C |
1734905428 | 13.88 Volt | 310 Pkt | 30 Pkt | 35 Pkt | 14.8 C |
1734902729 | 13.88 Volt | 360 Pkt | 30 Pkt | 49 Pkt | 14.8 C |
1734900029 | 13.88 Volt | 320 Pkt | 30 Pkt | 51 Pkt | 14.9 C |
1734897329 | 13.88 Volt | 370 Pkt | 30 Pkt | 50 Pkt | 14.9 C |
1734894629 | 13.73 Volt | 420 Pkt | 30 Pkt | 61 Pkt | 14.9 C |
1734891930 | 13.88 Volt | 380 Pkt | 20 Pkt | 53 Pkt | 14.9 C |
1734891929 | 13.88 Volt | 380 Pkt | 20 Pkt | 53 Pkt | 14.9 C |
1734889229 | 13.88 Volt | 320 Pkt | 30 Pkt | 63 Pkt | 14.9 C |
1734886529 | 13.88 Volt | 310 Pkt | 20 Pkt | 46 Pkt | 14.9 C |
1734883829 | 13.88 Volt | 320 Pkt | 20 Pkt | 25 Pkt | 15 C |
1734881129 | 13.88 Volt | 350 Pkt | 20 Pkt | 73 Pkt | 15 C |
1734878430 | 13.88 Volt | 350 Pkt | 20 Pkt | 49 Pkt | 15 C |
1734878429 | 13.88 Volt | 350 Pkt | 20 Pkt | 49 Pkt | 15 C |
1734875730 | 13.88 Volt | 400 Pkt | 30 Pkt | 64 Pkt | 15.1 C |
*Used Equation Coefficients:
Uin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Rx10m: 0, 1, 0
Temp: 0, 0.1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)